Franzen acoustic performance doors

Acoustic performance door Franzen SN-1 System Schröders

single-leaf acoustic performance steel door

Acoustic performance * depending on size see
expert opinion SEII-16-0211-Hrd, TÜV Nord (de)

combinable with additional performance characteristics
Thermal transmittance

UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1

Installation in external walls
(optional)

CE-Zeichen marked according to DIN EN 14351-1

Air tightness
(optional)

up to class 4 according to EN 12207 (± 600 Pa)
expert opinion no. 11-000082-PR01

Resistance to wind load
(optional)

up to class C5 according to EN 12210 (± 2,000 Pa)
expert opinion no. 11-000082-PR01

Watertightness
(optional)

up to class 8A according to EN 12208 (+ 450 Pa)
expert opinion no. 11-000082-PR01

Resistance to positive and negative pressure
(optional)

according to DIN EN 12211 (up to 5,000 Pa)
expert opinion no. 16-003037-PR01

Behavior between different climates
(optional)

class 2 (d + e) according to EN 12219 (deflection)

Ability to release
(optional)

according to DIN EN 14351-1
proven for doors in escape and rescue routes

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF) Logo ATEX
Potential equalisation
(optional)

according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540


combinable with additional performance characteristics
Fire resistance
(optional)

tested EI290 (fire door EI290 Franzen TSN-11)
tested EI260 (fire door EI260 Franzen TSN-3)
tested EI230 (fire door EI230 Franzen TSN-1)

according to EN 1634-1

T90 (fire door T90 Franzen TSN-11)
T30 (fire door T30 Franzen TSN-1)

mit allgemeiner bauaufsichtlicher Zulassung (German approval)

Smoke control
(optional)

Sa4 / S200 tested according to EN 1634-3

(e.g. smoke control door Franzen RSN-1 CE)

Burglar resistance
(optional)

up to RC4 (z.B. burglar protection door Franzen ESN-1)

according to DIN EN 1627 ff


Technical data
Dimensions
(rough building dimension)
width from 600 mm up to 1,400 mm
height from 1,750 mm up to 3,050 mm
Dimensions flap
width von 600 mm up to 1,400 mm
height from 600 mm up to 3,050 mm

deviating special sizes possible with corresponding individual proof under building law
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm

thin rebate design

insulating insert
  • optional full-face glued and pressed with cover plate,
    thus particularly smooth and even door leaf

securing pins

Frame

corner frame

frame-system "ZNG"

  • optional enclosing frame
  • optional block frame
Sealing system

see acoustic performance - measurement reports

Glass inset
(optional)

glass dimensions and -form variable

  • sound insulation glass ≥ 44 dB
  • optional with intermediate glass inset bars
  • optional with port-hole

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

2/3-part KO door hinges
with patented easy-running bearings as easy running doors

  • optional door hinge with 3D adjustment
  • heavy-duty hinges available on request
Fittings
  • optional any approved handle set according to EN 1906 resp. EN 179
  • optional panic bar handle or push bar according to EN 1125
Locking

various locking systems possible
profile cylinder prepared (cylinder on-site)

  • optional panic locking according to EN 179 resp. EN 1125
Self-closing
(optional)

door closer according to DIN EN 1154

  • optional spring hinge for smaller doors / flaps
Installation

wall according to acoustic performance requirements

  • optional blunt installation in soffit
  • optional installation on the wall plate
Optional
  • lock control
  • automated opening
  • motor locks ( also in 3-way locking)
  • powder coating in RAL colors
  • prison cell doors (special locking and food flap)
  • special solutions according to request and customer requirements

The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information.

Individual configurations may be required when combining different performance characteristics.

Our team will be happy to assist you with the individual planning of your requirements.