single-leaf steel fire door |
||||||||||||||||||
Fire resistance |
T-30 |
||||||||||||||||||
combinable with additional performance characteristics | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Smoke control
(optional) |
Smoke control according to DIN 18095 RS-1
|
||||||||||||||||||
Bullet resistance |
class FB6 - test report S-23-0208-04/05 Beschussamt Ulm tested according to EN 1522/1523 |
||||||||||||||||||
Burglar resistance
(optional) |
RC4 - classification report no. 22-5/15.119, PIV-Velbert
according to DIN EN 1627 ff |
||||||||||||||||||
Acoustic performance
(optional) |
up to RW (C;Ctr) = 53 (-1;-5) dB according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717 |
||||||||||||||||||
Thermal transmittance |
UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1 |
||||||||||||||||||
Air tightness
(optional) |
up to class 4 according to EN 12207 (± 600 Pa) |
||||||||||||||||||
Resistance to positive and negative pressure
(optional) |
according to DIN EN 12211 (up to 5,000 Pa) |
||||||||||||||||||
Flush with surface
(optional) |
|||||||||||||||||||
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)
![]() |
||||||||||||||||||
Potential equalisation
(optional) |
according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540 |
||||||||||||||||||
Technical data | |||||||||||||||||||
Dimensions
(rough building dimension) |
|
||||||||||||||||||
Dimensions flap
(rough building dimension) |
|
||||||||||||||||||
Overhead panel |
|
||||||||||||||||||
Side panel(s) |
|
||||||||||||||||||
Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
thin rebate design insulating insert
securing pins |
||||||||||||||||||
Frame |
corner frame
frame-system "ZNG"
|
||||||||||||||||||
Floor seal |
required for smoke control, acoustic performance, air tightness
|
||||||||||||||||||
Glass inset
(optional) |
glass dimensions and -form variable minimum frieze width: 130 mm
glass inset bars with concealed screw connection (for rectangular glass inset) |
||||||||||||||||||
Hinges |
2/3-part KO door hinges
|
||||||||||||||||||
Fittings |
|
||||||||||||||||||
Locking |
single locking according to EN 12209, depending on version multi-point locking
|
||||||||||||||||||
Self-closing |
door closer according to DIN EN 1154
|
||||||||||||||||||
Installation |
|
||||||||||||||||||
Optional |
|
||||||||||||||||||
The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information. Individual configurations may be required when combining different performance characteristics. Our team will be happy to assist you with the individual planning of your requirements. |