Franzen fire doors

Fire resistance door Franzen TSN-1 System Schröders

single-leaf steel fire door

Fire resistance

T-30
Allgemeine bauaufsichtliche Zulassung Nr. Z 6.20-1909, DIBt Berlin


combinable with additional performance characteristics
Smoke control
(optional)

Smoke control according to DIN 18095 RS-1
Allgemeine bauaufsichtliche Zulassung Nr. Z 6.20-1909, DIBt Berlin

Bullet resistance

class FB6 - test report S-23-0208-04/05 Beschussamt Ulm
class FB4 - test report S-23-0208-01/02 Beschussamt Ulm

tested according to EN 1522/1523

Burglar resistance
(optional)

RC4 - classification report no. 22-5/15.119, PIV-Velbert
RC3 - classification report no. 22-4/15.117, PIV-Velbert
RC2 - classification report no. 45-47/22, PIV-Velbert
RC1 - classification report no. 212 24294, ift Rosenheim

according to DIN EN 1627 ff

Acoustic performance
(optional)

up to RW (C;Ctr) = 53 (-1;-5) dB

according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717

proof of airborne sound insulation for security doors
(measurement reports, test reports, expert opinions)

Thermal transmittance

UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1

Air tightness
(optional)

up to class 4 according to EN 12207 (± 600 Pa)
expert opinion no. 11-000082-PR01

Resistance to positive and negative pressure
(optional)

according to DIN EN 12211 (up to 5,000 Pa)
expert opinion no. 16-003037-PR01

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF) Logo ATEX
Potential equalisation
(optional)

according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540


Technical data
Dimensions
(rough building dimension)
width from 625 mm up to 1,500 mm
height from 1,750 mm up to 3,250 mm
with overhead panel total height up to 3,165 mm
height overhead panel up to 1,000 mm
with side panel total width up to 3,430 mm
width per side panel up to 1,000 mm
Dimensions flap
(rough building dimension)
width from 685 mm up to 1,255 mm
height from 685 mm up to 1,750 mm

deviating special sizes possible with corresponding individual proof under building law
Overhead panel
  • optional width fixed overhead panel
Side panel(s)
  • optional with fixed side panel(s)
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm

thin rebate design

insulating insert
  • optional full-face glued and pressed with cover plate,
    thus particularly smooth and even door leaf

securing pins

Frame

corner frame

frame-system "ZNG"
with flush clipped in Thelesol® fire protection strips and elastic rubber seal

  • optional enclosing frame
  • optional block frame
Floor seal

required for smoke control, acoustic performance, air tightness

  • optional lowerable floor seal RSI
  • optional time-delayed closing floor seal RSI-V
    (not for acoustic performance, increased airtightness, resistance to wind load, watertightness)
  • optional sliding seal / grinding seal
Glass inset
(optional)

glass dimensions and -form variable
(rectangular glass inset max. 980 mm x 2,180 mm)

minimum frieze width: 130 mm

  • optional with intermediate glass inset bars
  • optional with port-hole

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

2/3-part KO door hinges
with patented easy-running bearings as easy running doors

  • optional door hinge with 3D adjustment
  • heavy-duty hinges available on request
Fittings
  • optional any approved handle set according to EN 1906 resp. EN 179
  • optional panic bar handle or push bar according to EN 1125
Locking

single locking according to EN 12209, depending on version multi-point locking
profile cylinder prepared (cylinder on-site)

  • optional panic locking according to EN 179 resp. EN 1125
Self-closing

door closer according to DIN EN 1154

  • optional spring hinge for smaller doors / flaps
Installation
  • in masonry (thk ≥ 115 mm)
  • in concrete (thk ≥ 100 mm)
  • in aerated concrete (thk ≥ 150 mm)
  • in mounting walls min. F90 (thk ≥ 100 mm)
  • in encased steel columns min. F90 (thk ≥ 100 mm)
  • optional blunt installation in soffit
  • optional installation on the wall plate
  • approved for installation at great heights (installation not at floor level: height on one or both sides > 500 mm above ground level - e.g. as manhole door/flap) with lower fire and smoke seal - also thresholdless
Optional
  • lock control
  • automated opening
  • motor locks (also in 3-way locking)
  • powder coating in RAL colors
  • prison cell doors (special locking and food flap)
  • special solutions according to request and customer requirements

The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information.

Individual configurations may be required when combining different performance characteristics.

Our team will be happy to assist you with the individual planning of your requirements.