Grafik: Logo Franzen Feuerschutztüren
Franzen Feuerschutztüren
Zechenring 23
D-41836 Hückelhoven

phone +49(0)2433/93919‑0

Franzen multi purpose steel doors

Double-leaf multi purpose steel door ISN-2

Franzen multi purpose door ISN-2 "System Schröders"
internal hinged door according to DIN ENV 14351-2 (draft)

Combinable with additional performance characteristics:

Air tightness
(optional)

up to class 3 according to EN 12207 (up to 600 Pa)

expert opinion no. 40-40/12.120, PIV Velbert
Thermal transmittance
(optional)

UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1

Resistance to wind load
(optional)

up to class C4 (up to 2,000 Pa) according to EN 12210

expert opinion no. 40-40/12.120, PIV Velbert
Watertightness
(optional)

up to class 3A according to EN 12208

expert opinion no. 40-40/12.120, PIV Velbert
Resistance to positive and negative pressure
(optional)

up to 3.800 Pa according to DIN EN 12211

expert opinion no. 40-52/16.120
Behavior between different climates
(optional)

class 2 (d + e) according to EN 12219 (deflection)

Ability to release
(optional)
according to DIN EN 14351-1

proven for doors in escape and rescue routes

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
Logo ATEX For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)

Performance characteristics combinable with further Franzen door types:

Fire resistance
(optional)

T90 (fire door T90 Franzen TSN-12)
T30 (fire door T30 Franzen TSN-2)

mit allgemeiner bauaufsichtlicher Zulassung (German approval)

Smoke control
(optional)

tested Sa / S200 (z.B. fire door Franzen TSN-2)

according to EN 1634-3

Burglar resistance
(optional)

up to RC4 (e.g. burglar resistance dor Franzen ESN-2)

according to EN 1627

Acoustic performance
(optional)

up to RW (C;Ctr) = 48 (-1;-5) dB e.g. acoustic performance door Franzen SN-2

according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717

Technical data
Dimensions
(rough building dimension)

for performance characteristic airtightness, resistance to wind load, watertightness or resistance to positive and negative pressure limited to

width up to 2,500 mm
height up to 2,500 mm
 
with overhead panel height max. 3,500 mm
Overhead panel
  • optional with fixed overhead panel
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm

  • thin rebate design
    • optional thick rebate design
Frame
  • frame-system "ZNG" with flush clipped in profile strips
  • or
  • frame-system "ZG"
  • (see installation variants)
  • corner frame
  • optional enclosing frame
  • optional block frame

with elastic rubber seal
(seal type depending on performance characteristic)

Floor seal

required for smoke control, acoustic performance, air tightness

  • optional lowerable floor seal or
  • sliding seal
  • stop seal
Glass inset
(optional)

glass dimensions and -form variable

minimum frieze width: 90 mm

  • optional with intermediate glass inset bars
  • optional with port-hole
  • optional in overhead panel

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

per leaf 2/3-part KO door hinges
with patented easy-running bearings as easy running doors

  • optional door hinge with 3D adjustment
Fittings

various fittings possible

Locking

various locking systems possible

active leaf

profile cylinder prepared (cylinder on-site)

Self-closing

both leafs with door closer according to DIN EN 1154 resp. EN 1155
with door closing sequence control according to EN1158

Installation
  • in masonry
  • in concrete
  • in aerated concrete
  • in mounting walls
  • in encased steel columns
  • optional blunt installation in soffit
  • optional installation on the wall plate
Marking

CE-Zeichen marking only possible after publication of the standard DIN EN 14351-2

Optional
  • lock control
  • automated opening
  • motor locks ( also in 3-way locking)
  • powder coating in RAL colors
  • prison cell doors (special locking and food flap)
  • special solutions according to request and customer requirements

The information given refers to the usual configurations. Individual configurations may be required when combining different performance characteristics.

Our team will be happy to assist you with the individual planning of your requirements.

  • multi purpose door ISN-2
    Franzen ISN-2double-leaf multi purpose door

ISN-2 Downloads