double-leaf internal door |
Installation in internal walls |
according to DIN ENV 14351-2 (draft) |
combinable with additional performance characteristics | |
---|---|
Thermal transmittance |
UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1 |
Air tightness
(optional) |
up to class 3 according to EN 12207 (± 600 Pa) |
Resistance to wind load
(optional) |
up to class C4 according to EN 12210 (± 1,600 Pa) |
Watertightness
(optional) |
up to class 3A according to EN 12208 (± 150 Pa) |
Resistance to positive and negative pressure
(optional) |
according to DIN EN 12211 (up to 3,800 Pa) |
Behavior between different climates
(optional) |
class 2 (d + e) according to EN 12219 (deflection) |
Ability to release
(optional) |
according to DIN EN 14351-1 |
Flush with surface
(optional) |
|
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)
![]() |
Potential equalisation
(optional) |
according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540 |
performance characteristics combinable with further Franzen door types: | |
Fire resistance (optional) |
T90 (fire door T90 Franzen TSN-12) mit allgemeiner bauaufsichtlicher Zulassung (German approval) |
Smoke control
(optional) |
tested Sa4 / S200 (z.B. fire door Franzen TSN-2) according to EN 1634-3 |
Burglar resistance (optional) |
up to RC4 (e.g. burglar resistance dor Franzen ESN-2) according to EN 1627 |
Acoustic performance
(optional) |
up to RW (C;Ctr) = 48 (-1;-5) dB e.g. acoustic performance door Franzen SN-2 according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717 |
Technical data | |
Dimensions
(rough building dimension) |
Without specifications |
Overhead panel |
|
Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
thin rebate design securing pins |
Frame |
corner frame frame-system "ZNG" with flush clipped in profile strips
with elastic rubber seal |
Floor seal |
depending on performance characteristic
|
Glass inset
(optional) |
glass dimensions and -form variable minimum frieze width: 90 mm
glass inset bars with concealed screw connection (for rectangular glass inset) |
Hinges |
2/3-part KO door hinges
|
Fittings |
various fittings possible |
Locking |
various locking systems possible active leafprofile cylinder prepared (cylinder on-site) |
Self-closing |
both leafs with door closer according to DIN EN 1154 resp. EN 1155 |
Installation |
|
Optional |
|
The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information. Individual configurations may be required when combining different performance characteristics. Our team will be happy to assist you with the individual planning of your requirements. |