Franzen multi purpose steel doors
Double-leaf multi purpose steel door ISN-2
Franzen multi purpose door ISN-2 "System Schröders" | |
---|---|
internal hinged door according to DIN ENV 14351-2 (draft) | |
Combinable with additional performance characteristics: |
|
Air tightness
(optional) |
up to class 3 according to EN 12207 (up to 600 Pa) expert opinion no. 40-40/12.120, PIV Velbert |
Thermal transmittance (optional) |
UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1 |
Resistance to wind load
(optional) |
up to class C4 (up to 2,000 Pa) according to EN 12210 expert opinion no. 40-40/12.120, PIV Velbert |
Watertightness
(optional) |
up to class 3A according to EN 12208 expert opinion no. 40-40/12.120, PIV Velbert |
Resistance to positive and negative pressure
(optional) |
up to 3.800 Pa according to DIN EN 12211 expert opinion no. 40-52/16.120 |
Behavior between different climates
(optional) |
class 2 (d + e) according to EN 12219 (deflection) |
Ability to release
(optional) |
according to DIN EN 14351-1 proven for doors in escape and rescue routes |
Flush with surface
(optional) |
|
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF) |
Performance characteristics combinable with further Franzen door types: |
|
Fire resistance (optional) |
T90 (fire door T90 Franzen TSN-12) mit allgemeiner bauaufsichtlicher Zulassung (German approval) |
Smoke control
(optional) |
tested Sa / S200 (z.B. fire door Franzen TSN-2) according to EN 1634-3 |
Burglar resistance (optional) |
up to RC4 (e.g. burglar resistance dor Franzen ESN-2) according to EN 1627 |
Acoustic performance
(optional) |
up to RW (C;Ctr) = 48 (-1;-5) dB e.g. acoustic performance door Franzen SN-2 according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717 |
Technical data | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dimensions
(rough building dimension) |
|
|||||||||||||||
Overhead panel |
|
|||||||||||||||
Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
|
|||||||||||||||
Frame |
with elastic rubber seal |
|||||||||||||||
Floor seal |
required for smoke control, acoustic performance, air tightness
|
|||||||||||||||
Glass inset
(optional) |
glass dimensions and -form variable minimum frieze width: 90 mm
glass inset bars with concealed screw connection (for rectangular glass inset) |
|||||||||||||||
Hinges |
per leaf 2/3-part KO door hinges
|
|||||||||||||||
Fittings |
various fittings possible |
|||||||||||||||
Locking |
various locking systems possible active leafprofile cylinder prepared (cylinder on-site) |
|||||||||||||||
Self-closing |
both leafs with door closer according to DIN EN 1154 resp. EN 1155 |
|||||||||||||||
Installation |
|
|||||||||||||||
Marking |
marking only possible after publication of the standard DIN EN 14351-2 |
|||||||||||||||
Optional |
|
|||||||||||||||
The information given refers to the usual configurations. Individual configurations may be required when combining different performance characteristics. Our team will be happy to assist you with the individual planning of your requirements. |
-
Franzen ISN-2double-leaf multi purpose door