double-leaf burglar resistance steel door |
||||||||||||||||||||
|
|||||||||||||||||||||
Burglar resistance |
RC4 - classification report no. 22-18/04 ERW, PIV Velbert
according to EN 1627 ff |
||||||||||||||||||||
combinable with additional performance characteristics | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Acoustic performance
(optional) |
up to RW (C;Ctr) = 48 (-1;-5) dB according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717 |
||||||||||||||||||||
Thermal transmittance (optional) |
UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1 |
||||||||||||||||||||
Air tightness
(optional) |
up to class 3 according to EN 12207 (± 600 Pa) |
||||||||||||||||||||
Installation in external walls
(optional) |
|
||||||||||||||||||||
Resistance to wind load
(optional) |
up to class C4 according to EN 12210 (± 1,600 Pa) |
||||||||||||||||||||
Watertightness
(optional) |
up to class 3A according to EN 12208 (± 150 Pa) |
||||||||||||||||||||
Resistance to positive and negative pressure
(optional) |
according to DIN EN 12211 (up to 3,800 Pa) |
||||||||||||||||||||
Behavior between different climates
(optional) |
class 2 (d + e) according to EN 12219 (deflection) |
||||||||||||||||||||
Ability to release
(optional) |
according to DIN EN 14351-1 proven for doors in escape and rescue routes |
||||||||||||||||||||
Flush with surface
(optional) |
|||||||||||||||||||||
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)
![]() |
||||||||||||||||||||
Arc fault protection
(optional) |
pressure resistance up to 31,000 Pa in accordance with IEC 62271-202-2022, section 7.102 and Annex A |
||||||||||||||||||||
Potential equalisation
(optional) |
according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540 |
||||||||||||||||||||
performance characteristics combinable with further Franzen door types: | |||||||||||||||||||||
Fire resistance (optional) |
tested EI290 (fire door EI290 Franzen TSN-12) according to EN 1634-1
T90 (fire door T90 Franzen TSN-12) mit allgemeiner bauaufsichtlicher Zulassung (German approval) |
||||||||||||||||||||
Smoke control
(optional) |
RS (e.g. smoke control door Franzen RSN-2) according to DIN 18095 |
||||||||||||||||||||
Technical data | |||||||||||||||||||||
Dimensions
(rough building dimension) |
|
||||||||||||||||||||
Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
thin rebate design insulating insert
securing pins |
||||||||||||||||||||
Frame |
corner frame
frame-system "ZNG"
|
||||||||||||||||||||
Rebate protection | rebate protection through ESP safety profile (patent-protected) | ||||||||||||||||||||
Floor seal |
depending on performance characteristic
|
||||||||||||||||||||
Glass inset
(optional) |
glass dimensions and -form variable minimum frieze width: 130 mm
glass inset bars with concealed screw connection (for rectangular glass inset) |
||||||||||||||||||||
Ventilation (optional) |
gill ventilation, louvre ventilation, bar grille | ||||||||||||||||||||
Hinges |
2/3-part KO door hinges
|
||||||||||||||||||||
Fittings |
|
||||||||||||||||||||
Locking |
|
||||||||||||||||||||
Installation |
|
||||||||||||||||||||
Optional |
|
||||||||||||||||||||
The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information. Individual configurations may be required when combining different performance characteristics. Our team will be happy to assist you with the individual planning of your requirements. |