double-leaf smoke control steel door |
|||||||||||||||||||||
Smoke control | tested according to DIN 18095 RS-2
Allgemeines bauaufsichtliches Prüfzeugnis Nr. P-BWU03-I 17.67.16, MPA Stuttgart - Otto-Graf-Institut |
|||||||||||||||||||||
combinable with additional performance characteristics | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Burglar resistance
(optional) |
RC4 - classification report no. 22-7/15.119, PIV-Velbert
according to DIN EN 1627 ff |
|||||||||||||||||||||
Thermal transmittance (optional) |
UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1 |
|||||||||||||||||||||
Air tightness
(optional) |
up to class 3 according to EN 12207 (± 600 Pa) |
|||||||||||||||||||||
Resistance to wind load
(optional) |
up to class C4 according to EN 12210 (± 1,600 Pa) |
|||||||||||||||||||||
Watertightness
(optional) |
up to class 3A according to EN 12208 (± 150 Pa) |
|||||||||||||||||||||
Resistance to positive and negative pressure
(optional) |
according to DIN EN 12211 (up to 3,800 Pa) |
|||||||||||||||||||||
Flush with surface
(optional) |
||||||||||||||||||||||
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)
![]() |
|||||||||||||||||||||
Potential equalisation
(optional) |
according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540 |
|||||||||||||||||||||
performance characteristics combinable with further Franzen door types: | ||||||||||||||||||||||
Fire resistance (optional) |
T90 (fire door T90 Franzen TSN-12) mit allgemeiner bauaufsichtlicher Zulassung (German approval) |
|||||||||||||||||||||
Technical data | ||||||||||||||||||||||
Dimensions
(rough building dimension) |
|
|||||||||||||||||||||
Overhead panel |
|
|||||||||||||||||||||
Side panel(s) |
|
|||||||||||||||||||||
Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
thin rebate design insulating insert
leaf weight ca. 20 kg/m securing pins |
|||||||||||||||||||||
Frame |
corner frame frame-system "ZNG" with elastic rubber seal
|
|||||||||||||||||||||
Floor seal |
lowerable floor seal RSI
|
|||||||||||||||||||||
Glass inset
(optional) |
glass dimensions and -form variable minimum frieze width: 90 mm
glass inset bars with concealed screw connection (for rectangular glass inset) |
|||||||||||||||||||||
Hinges |
2/3-part KO door hinges
|
|||||||||||||||||||||
Fittings |
active leaf
|
|||||||||||||||||||||
Locking |
active leaf
single locking according to EN 12209, depending on version multi-point locking
internal snap bolt (locking upwards)
|
|||||||||||||||||||||
Self-closing |
both leafs with door closer according to DIN EN 1154 resp. EN 1155 |
|||||||||||||||||||||
Installation |
|
|||||||||||||||||||||
Marking |
Conformity mark - "Ü"
|
|||||||||||||||||||||
Optional |
|
|||||||||||||||||||||
The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information. Individual configurations may be required when combining different performance characteristics. Our team will be happy to assist you with the individual planning of your requirements. |