Franzen smoke control doors
Double-leaf smoke control door RSN-2 according to DIN 18095
Franzen smoke control door RSN-2 "System Schröders" | |
---|---|
Double-leaf smoke control steel door | |
Smoke control | tested according to DIN 18095 RS-2
Allgemeines bauaufsichtliches Prüfzeugnis Nr. P-BWU03-I 17.67.16, MPA Stuttgart - Otto-Graf-Institut |
Combinable with additional performance characteristics: |
|
Burglar resistance
(optional) |
RC4 - classification report no. 22-7/15.119, PIV-Velbert
according to DIN EN 1627 ff |
Thermal transmittance (optional) |
UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1 |
Air tightness
(optional) |
up to class 3 according to EN 12207 (up to 600 Pa) expert opinion no. 40-40/12.120, PIV Velbert |
Resistance to wind load
(optional) |
up to class C4 (up to 2,000 Pa) according to EN 12210 expert opinion no. 40-40/12.120, PIV Velbert |
Watertightness
(optional) |
up to class 3A according to EN 12208 expert opinion no. 40-40/12.120, PIV Velbert |
Resistance to positive and negative pressure
(optional) |
up to 3.800 Pa according to DIN EN 12211 expert opinion no. 40-52/16.120 |
Flush with surface
(optional) |
|
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF) |
Performance characteristics combinable with further Franzen door types: |
|
Fire resistance (optional) |
T90 (fire door T90 Franzen TSN-12) mit allgemeiner bauaufsichtlicher Zulassung (German approval) |
Technical data | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dimensions
(rough building dimension) |
|
||||||||||||||||||
Overhead panel |
|
||||||||||||||||||
Side panel |
|
||||||||||||||||||
Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
|
||||||||||||||||||
Frame |
with elastic rubber seal |
||||||||||||||||||
Floor seal |
|
||||||||||||||||||
Glass inset
(optional) |
glass dimensions and -form variable minimum frieze width: 90 mm
glass inset bars with concealed screw connection (for rectangular glass inset) |
||||||||||||||||||
Hinges |
per leaf 2/3-part KO door hinges
|
||||||||||||||||||
Fittings |
active leaf
for version RC: Protective fitting ES-1 up to ES-3 |
||||||||||||||||||
Locking |
active leaf
single locking according to EN 12209, depending on version multi-point locking
internal snap bolt (locking upwards)
securing pins at both leafs
|
||||||||||||||||||
Self-closing |
both leafs with door closer according to DIN EN 1154 resp. EN 1155 |
||||||||||||||||||
Installation |
|
||||||||||||||||||
Marking |
Conformity mark - "Ü"
|
||||||||||||||||||