Franzen smoke control doors

Smoke control door Franzen RSN-2 System Schröders

double-leaf smoke control steel door

Smoke control tested according to DIN 18095 RS-2
Allgemeines bauaufsichtliches Prüfzeugnis Nr. P-BWU03-I 17.67.16,
MPA Stuttgart - Otto-Graf-Institut

combinable with additional performance characteristics
Burglar resistance
(optional)

RC4 - classification report no. 22-7/15.119, PIV-Velbert
RC3 - classification report no. 22-6/15.117, PIV-Velbert
RC2 - classification report no. 212 24303, ift Rosenheim
RC1 - classification report no. 212 24302, ift Rosenheim

according to DIN EN 1627 ff

Thermal transmittance
(optional)

UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1

Air tightness
(optional)

up to class 3 according to EN 12207 (± 600 Pa)
expert opinion no. 40-40/12.120, PIV Velbert

Resistance to wind load
(optional)

up to class C4 according to EN 12210 (± 1,600 Pa)
expert opinion no. 40-40/12.120, PIV Velbert

Watertightness
(optional)

up to class 3A according to EN 12208 (± 150 Pa)
expert opinion no. 40-40/12.120, PIV Velbert

Resistance to positive and negative pressure
(optional)

according to DIN EN 12211 (up to 3,800 Pa)
expert opinion no. 40-52/16.120

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF) Logo ATEX
Potential equalisation
(optional)

according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540


performance characteristics combinable with further Franzen door types:
Fire resistance
(optional)

T90 (fire door T90 Franzen TSN-12)
T30 (fire door T30 Franzen TSN-2)

mit allgemeiner bauaufsichtlicher Zulassung (German approval)


Technical data
Dimensions
(rough building dimension)
width from 1,375 mm up to 4,500 mm
height from 1,750 mm up to 4,500 mm
with overhead panel total height max. 3,500 mm
height overhead panel max. 1,000 mm
with side panel(s) total width max. 4,000 mm
width per side panel max. 1,000 mm

deviating special sizes possible with corresponding individual proof under building law
Overhead panel
  • optional width fixed overhead panel
Side panel(s)
  • optional with fixed side panel(s)
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm

thin rebate design

insulating insert
  • optional full-face glued and pressed with cover plate,
    thus particularly smooth and even door leaf

leaf weight ca. 20 kg/m

securing pins

Frame

corner frame

frame-system "ZNG" with elastic rubber seal

  • optional enclosing frame
  • optional block frame
Floor seal

lowerable floor seal RSI

  • optional time-delayed closing floor seal RSI-V
    (not for acoustic performance, increased airtightness, resistance to wind load, watertightness)
  • optional sliding seal / grinding seal
Glass inset
(optional)

glass dimensions and -form variable
(rectangular glass inset max. 1,260 mm x 3,020 mm)

minimum frieze width: 90 mm

  • optional with intermediate glass inset bars
  • optional with port-hole
  • optional also in overhead / side panels

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

2/3-part KO door hinges
with patented easy-running bearings as easy running doors

  • optional door hinge with 3D adjustment
  • heavy-duty hinges available on request
Fittings active leaf
  • optional any approved handle set according to EN 1906 resp. EN 179
  • optional panic bar handle or push bar according to EN 1125
Locking active leaf

single locking according to EN 12209, depending on version multi-point locking
profile cylinder prepared (cylinder on-site)

fixed leaf

internal snap bolt (locking upwards)
depending on version, with locking upwards and downwards (rebate shoot bolt, shoot bolt lock)

  • optional panic locking according to EN 179 resp. EN 1125
Self-closing

both leafs with door closer according to DIN EN 1154 resp. EN 1155
with door closing sequence control according to EN1158

Installation
  • in masonry (thk ≥ 115 mm)
  • in concrete (thk ≥ 100 mm)
  • in aerated concrete (thk ≥ 150 mm)
  • in mounting walls min. F30 (thk ≥ 100 mm)
  • optional blunt installation in soffit
  • optional installation on the wall plate
Marking

Conformity mark - "Ü"
according to German conformity mark regulation

Optional
  • lock control
  • automated opening
  • motor locks ( also in 3-way locking)
  • powder coating in RAL colors
  • prison cell doors (special locking and food flap)
  • special solutions according to request and customer requirements

The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information.

Individual configurations may be required when combining different performance characteristics.

Our team will be happy to assist you with the individual planning of your requirements.