Franzen fire doors

Fire resistance door Franzen TSN-2 CE System Schröders

double-leaf fire resistant steel door / gate EI230-Sa4-C5

CE-marking marked with declaration of performance

Fire resistance

EI230-Sa4 tested according to EN 1634-1

  • as a gate according to DIN EN 13241
  • as an external door according to DIN EN 14351-1
Thermal transmittance

UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1


combinable with additional performance characteristics
Smoke control
(optional)
S200 tested according to EN 1634-3
Burglar resistance
(optional)

RC4 - classification report no. 22-7/15.119, PIV-Velbert
RC3 - classification report no. 22-6/15.117, PIV-Velbert
RC2 - classification report no. 212 24303, ift Rosenheim
RC1 - classification report no. 212 24302, ift Rosenheim

according to DIN EN 1627 ff

Acoustic performance
(optional)

up to RW (C;Ctr) = 48 (-1;-5) dB

according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717

proof of airborne sound insulation for security doors
(measurement reports, test reports, expert opinions)

Air tightness
(optional)

up to class 3 according to EN 12207 (± 600 Pa)
expert opinion no. 40-40/12.120, PIV Velbert

Resistance to wind load
(optional)

up to class C4 according to EN 12210 (± 1,600 Pa)
expert opinion no. 40-40/12.120, PIV Velbert

Watertightness
(optional)

up to class 3A according to EN 12208 (± 150 Pa)
expert opinion no. 40-40/12.120, PIV Velbert

Resistance to positive and negative pressure
(optional)

according to DIN EN 12211 (up to 3,800 Pa)
expert opinion no. 40-52/16.120

Behavior between different climates
(optional)

class 2 (d + e) according to EN 12219 (deflection)

Ability to release
(optional)

according to DIN EN 16034
hold-open device according to DIN EN 14637

according to DIN EN 14351-1
proven for doors in escape and rescue routes

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF) Logo ATEX
Potential equalisation
(optional)

according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540


Technical data
Dimensions
(rough building dimension)
width from 1,250 mm up to 4,600 mm
height from 1,900 mm up to 4,600 mm

deviating special sizes possible with corresponding individual proof under building law
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm

thin rebate design

insulating insert
  • optional full-face glued and pressed with cover plate,
    thus particularly smooth and even door leaf

securing pins

Frame

corner frame

frame-system "ZNG"
with flush clipped in Thelesol® fire protection strips and elastic rubber seal

  • optional enclosing frame
  • optional block frame
Floor seal

required for smoke control, acoustic performance, air tightness

  • optional lowerable floor seal or
  • sliding seal / grinding seal
Glass inset
(optional)

glass dimensions and -form variable
(rectangular glass inset max. 980 mm x 2,180 mm)

minimum frieze width: 130 mm

  • optional with intermediate glass inset bars
  • optional with port-hole

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

2/3-part KO door hinges
with patented easy-running bearings as easy running doors

  • optional door hinge with 3D adjustment
  • heavy-duty hinges available on request
Fittings active leaf
  • optional any approved handle set according to EN 1906 resp. EN 179
  • optional panic bar handle or push bar according to EN 1125
Locking active leaf

single locking according to EN 12209, depending on version multi-point locking
profile cylinder prepared (cylinder on-site)

fixed leaf

internal snap bolt (locking upwards)
depending on version, with locking upwards and downwards (rebate shoot bolt, shoot bolt lock)

  • optional panic locking according to EN 179 resp. EN 1125
Self-closing

both leafs with door closer according to DIN EN 1154 resp. EN 1155
with door closing sequence control according to EN1158

Installation
  • in masonry (thk ≥ 115 mm)
  • in concrete (thk ≥ 100 mm)
  • in aerated concrete (thk ≥ 150 mm)
  • in mounting walls min. F30 (thk ≥ 100 mm)
  • in encased steel columns min. F30 (thk ≥ 100 mm)
  • optional blunt installation in soffit
  • optional installation on the wall plate
  • approved for installation at great heights (installation not at floor level: height on one or both sides > 500 mm above ground level - e.g. as manhole door/flap) with lower fire and smoke seal - also thresholdless
Optional
  • lock control
  • automated opening
  • motor locks ( also in 3-way locking)
  • powder coating in RAL colors
  • prison cell doors (special locking and food flap)
  • special solutions according to request and customer requirements

The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information.

Individual configurations may be required when combining different performance characteristics.

Our team will be happy to assist you with the individual planning of your requirements.