single-leaf external steel door |
|
|
Installation in external walls
(optional) |
according to DIN EN 14351-1 |
Thermal transmittance |
UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1 |
combinable with additional performance characteristics | |
---|---|
Air tightness
(optional) |
up to class 4 according to EN 12207 (± 600 Pa) |
Resistance to wind load
(optional) |
up to class C5 according to EN 12210 (± 2,000 Pa) |
Watertightness
(optional) |
up to class 8A according to EN 12208 (+ 450 Pa) |
Resistance to positive and negative pressure
(optional) |
according to DIN EN 12211 (up to 5,000 Pa) |
Behavior between different climates
(optional) |
class 2 (d + e) according to EN 12219 (deflection) |
Ability to release
(optional) |
according to DIN EN 16034
according to DIN EN 14351-1 |
Flush with surface
(optional) |
|
arc fault protection | pressure resistance up to 31,000 Pa according to IEC 62271-202-2022, section 7.102 and annex A |
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)
![]() |
Potential equalisation
(optional) |
according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540 |
performance characteristics combinable with further Franzen door types: | |
Fire resistance
(optional) |
tested EI290 (fire door EI290 Franzen TSN-11) according to EN 1634-1 |
Smoke control
(optional) |
tested Sa4 / S200 (e.g. fire door Franzen TSN-1 CE) according to EN 1634-3 |
Burglar resistance
(optional) |
up to RC4 (e.g. burglar resistance door Franzen ESN-1) according to DIN EN 1627 ff |
Acoustic performance
(optional) |
up to RW (C;Ctr) = 53 (-1;-5) dB (e.g. acoustic performance door Franzen SN-1) according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717 |
Technical data | |
Dimensions
(rough building dimension) |
Without specifications |
Overhead panel (optional) |
|
Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
thin rebate design securing pins |
Frame |
corner frame frame-system "ZNG" with flush clipped in profile strips
with elastic rubber seal |
Floor seal |
depending on performance characteristic
|
Glass inset
(optional) |
glass dimensions and -form variable minimum frieze width: 90 mm
glass inset bars with concealed screw connection (for rectangular glass inset) |
Hinges |
2/3-part KO door hinges
|
Fittings |
various fittings possible |
Locking |
various locking systems possible cylinder prepared (cylinder on-site) |
Self-closing |
door closer according to DIN EN 1154
|
Installation |
|
Optional |
|
Optional |
|
The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information. Individual configurations may be required when combining different performance characteristics. Our team will be happy to assist you with the individual planning of your requirements. |