Franzen doors for transformer rooms
Double-leaf steel door for transformer rooms TR-2
Franzen transformer room door TR-2 | |
---|---|
Double-leaf steel door, double-walled for transformer stations | |
Optional |
marked |
Flush with surface
(optional) |
|
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF) |
Performance characteristics combinable with further Franzen door types: |
|
Fire resistance (optional) |
tested EI290 (fire door EI2 90 Franzen TSN-12) according to EN 1634-1
T90 (fire door T90 Franzen TSN-12) mit allgemeiner bauaufsichtlicher Zulassung (German approval) |
Smoke control
(optional) |
RS (e.g. smoke control door Franzen RSN-2) according to DIN 18095 |
Burglar resistance (optional) |
up to RC4 (e.g. burglar resistance dor Franzen ESN-2) according to EN 1627 |
Acoustic performance
(optional) |
up to RW (C;Ctr) = 48 (-1;-5) dB e.g. acoustic performance door Franzen SN-2 according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717 |
Thermal transmittance (optional) |
UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1 (e.g. external door Franzen ASN -1) |
Air tightness
(optional) |
up to class 4 (e.g. external door Franzen ASN -1) according to EN 12207 (up to 600 Pa) |
Installation in external walls
(optional) |
according to DIN EN 14351-1 marked |
Resistance to wind load
(optional) |
up to class C5 (up to 2,000 Pa) (e.g. external door Franzen ASN -1) according to EN 12210 |
Watertightness
(optional) |
up to class 8A (e.g. external door Franzen ASN -1) according to EN 12208 |
Resistance to positive and negative pressure
(optional) |
up to 5.000 Pa (e.g. external door Franzen ASN -1) according to DIN EN 12211 |
Behavior between different climates
(optional) |
class 2 (d + e) (e.g. external door Franzen ASN -1) according to EN 12219 (deflection) |
Ability to release
(optional) |
for doors in escape and rescue routes (e.g. external door Franzen ASN-1) |
Technical data | |
---|---|
Dimensions
(rough building dimension) |
no specification |
Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
|
Frame | no specification |
Floor seal | no specification |
Ventilation
(optional) |
ventilation size and number of ventilations depending on the transformer output |
Glass inset
(optional) |
glass dimensions and -form variable minimum frieze width: 90 mm
glass inset bars with concealed screw connection (for rectangular glass inset) |
Hinges |
per leaf 2/3-part KO door hinges
|
Fittings |
various fittings possible |
Locking |
various locking systems possible
active leaf |
Self-closing |
both leafs with door closer according to DIN EN 1154 resp. EN 1155 |
Installation |
|
Optional |
|
The information given refers to the usual configurations. Individual configurations may be required when combining different performance characteristics. Our team will be happy to assist you with the individual planning of your requirements. |