single-leaf smoke control door |
|||||||||||||||||||||
Smoke control | tested according to DIN 18095 RS-1
Allgemeines bauaufsichtliches Prüfzeugnis Nr.: P-BWU03-I 17.67.15, MPA Stuttgart - Otto-Graf-Institut |
|||||||||||||||||||||
combinable with additional performance characteristics | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Burglar resistance
(optional) |
RC4 - classification report no. 22-5/15.119, PIV-Velbert
according to DIN EN 1627 ff |
|||||||||||||||||||||
Thermal transmittance |
UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1 |
|||||||||||||||||||||
Air tightness
(optional) |
up to class 4 according to EN 12207 (± 600 Pa) |
|||||||||||||||||||||
Resistance to wind load
(optional) |
up to class C5 according to EN 12210 (± 2,000 Pa) |
|||||||||||||||||||||
Watertightness
(optional) |
up to class 8A according to EN 12208 (+ 450 Pa) |
|||||||||||||||||||||
Resistance to positive and negative pressure
(optional) |
according to DIN EN 12211 (up to 5,000 Pa) |
|||||||||||||||||||||
Flush with surface
(optional) |
||||||||||||||||||||||
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)
![]() |
|||||||||||||||||||||
Potential equalisation
(optional) |
according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540 |
|||||||||||||||||||||
performance characteristics combinable with further Franzen door types: | ||||||||||||||||||||||
Fire resistance
(optional) |
T90 (fire door T90 Franzen TSN-11) according to. allgemeine bauaufsichtliche Zulassung (German approval) |
|||||||||||||||||||||
Technical data | ||||||||||||||||||||||
Dimensions
(rough building dimension) |
|
|||||||||||||||||||||
Overhead panel |
|
|||||||||||||||||||||
Side panel(s) |
|
|||||||||||||||||||||
Door leaf |
leaf thickness 68 mm to 69 mm - smooth double-walled
thin rebate design insulating insert
leaf weight ca. 20 kg/m securing pins |
|||||||||||||||||||||
Frame |
corner frame frame-system "ZNG" with elastic rubber seal
|
|||||||||||||||||||||
Floor seal |
|
|||||||||||||||||||||
Glass inset
(optional) |
glass dimensions and -form variable minimum frieze width: 90 mm
glass inset bars with concealed screw connection (for rectangular glass inset) |
|||||||||||||||||||||
Hinges |
2/3-part KO door hinges
|
|||||||||||||||||||||
Fittings |
|
|||||||||||||||||||||
Locking |
single locking according to DIN 18250
|
|||||||||||||||||||||
Self-closing |
door closer according to DIN EN 1154
|
|||||||||||||||||||||
Installation |
|
|||||||||||||||||||||
Marking |
mark of conformity - "Ü"
|
|||||||||||||||||||||
Optional |
|
|||||||||||||||||||||
The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information. Individual configurations may be required when combining different performance characteristics. Our team will be happy to assist you with the individual planning of your requirements. |