Franzen bullet resistance doors

Bullet resistance door Franzen FBN-1 System Schröders

single leaf bullet resistance door

CE-marking marked with declaration of performance

Bullet resistance

class FB6 - test report S-23-0208-04/05 Beschussamt Ulm
class FB4 - test report S-23-0208-01/02 Beschussamt Ulm

tested according to EN 1522/1523


combinable with additional performance characteristics
Thermal transmittance
(optional)

UD-value ≥ 2,7 W/(m²K) according to EN ISO 10077-1

Burglar resistance
(optional)

RC4 - classification report no. 22-5/15.119, PIV-Velbert
RC3 - classification report no. 22-4/15.117, PIV-Velbert
RC2 - classification report no. 45-47/22, PIV-Velbert
RC1 - classification report no. 212 24294, ift Rosenheim

according to DIN EN 1627 ff

Acoustic performance
(optional)

up to RW (C;Ctr) = 53 (-1;-5) dB

according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717

proof of airborne sound insulation for security doors
(measurement reports, test reports, expert opinions)

Air tightness
(optional)

up to class 4 according to EN 12207 (± 600 Pa)
expert opinion no. 11-000082-PR01

Resistance to wind load
(optional)

up to class C5 according to EN 12210 (± 2,000 Pa)
expert opinion no. 11-000082-PR01

Watertightness
(optional)

up to class 8A according to EN 12208 (+ 450 Pa)
expert opinion no. 11-000082-PR01

Resistance to positive and negative pressure
(optional)

according to DIN EN 12211 (up to 5,000 Pa)
expert opinion no. 16-003037-PR01

Behavior between different climates
(optional)

class 2 (d + e) according to EN 12219 (deflection)

Ability to release
(optional)

according to DIN EN 16034
hold-open device according to DIN EN 14637

according to DIN EN 14351-1
proven for doors in escape and rescue routes

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF) Logo ATEX
Potential equalisation
(optional)

according to DIN EN 50310, DIN VDE 0100-410 bzw. DIN VDE 0100-540


Technical data
Dimensions
(rough building dimension)
door leaf area maximum 3 m²


Restrictions possible for additional performance properties e.g.
burglar resistance, acoustic performance, increased airtightness, and/or tightness against driving rain

deviating special sizes possible with corresponding individual proof

Door leaf

leaf thickness 69 mm - smooth double-walled
plate thickness 1.5 mm

thin rebate design

securing pins

Frame

corner frame

frame-system "ZNG"

seal depending on the performance characteristic

  • elastic rubber seal
  • silicone seal
  • optional block frame
  • optional surround frame
threshold

with bullet-resistant threshold

Doors without a bullet-resistant threshold always represent a safety risk, as a projectile can pass through the lower door gap.

Bodendichtung

depending on the performance characteristic

  • without seal
  • lowerable floor seal
  • stop seal
  • sliding seal / grinding seal
Glass inset
(optional)
  • FB4: Bullet-resistant rectangular glass inset according to EN 1063 BR4-NS

glass dimensions variable

minimum frieze width: 130 mm

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

2/3-part KO door hinges
with patented easy-running bearings as easy running doors

  • optional door hinge with 3D adjustment
  • heavy-duty hinges available on request
Fittings

ES3 fittings

  • optional visor fitting with 5-point locking system
Locking

various locking systems possible
profile cylinder prepared (cylinder on-site)

Self-closing

door closer according to DIN EN 1154

Installation

proven with mortared corner frame / attachment frame

  • in statically suitable, bullet-resistant walls according to the corresponding bullet resistance class
Optional
  • lock control
  • automated opening
  • motor locks (also in 3-way locking)
  • powder coating in RAL colors
  • prison cell doors (special locking and food flap)
  • special solutions according to request and customer requirements

The information given refer to usual configurations. Subject to change without notice. No liability for incorrect information.

Individual configurations may be required when combining different performance characteristics.

Our team will be happy to assist you with the individual planning of your requirements.