Franzen - ceiling flaps
Single-leaf multi purpose ceiling flap DKN-1
Franzen ceiling flap DKN-1 | |
---|---|
Single-leaf multipurpose ceiling flap | |
Installation in internal ceilings
(optional) |
according to DIN ENV 14351-2 marked |
Installation in external ceilings
(optional) |
according to DIN EN 14351-1 marked |
Combinable with additional performance characteristics: |
|
Burglar resistance
(optional) |
RC4 - classification report no. 22-5/15.119, PIV-Velbert
according to DIN EN 1627 ff |
Acoustic performance
(optional) |
up to RW (C;Ctr) = 42 (-1;-3) dB according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717 test report 81 16 48 52 29 -10, TÜV Nord
*Due to the approved dimensional range of the ceiling flap, the maximum acoustic performance value of RW (C;Ctr) = 45 (-1;-3) dB listed in the measurement report is reduced by 3dB to the above-mentioned value of RW (C;Ctr) = 42 (-1;-3) dB.
|
Thermal transmittance |
UD-value ≥ 1.3 W/(m²K) according to EN ISO 10077-1 |
Air tightness
(optional) |
up to class 4 according to EN 12207 (up to 600 Pa) expert opinion no. 11-000082-PR01 |
Resistance to positive and negative pressure
(optional) |
up to 5.000 Pa according to DIN EN 12211 expert opinion no. 16-003037-PR01 |
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF) |
Performance characteristics combinable with further Franzen ceiling flap types: |
|
Fire resistance
(optional) |
T90 |
Smoke control
(optional) |
tested according to DIN 18095 RS-1
(fire ceiling flap T90 Franzen THF) |
Technische Beschreibung | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Dimensions
(rough building dimension) |
|
|||||||||
Flap leaf |
leaf thickness 67 mm - smooth double-walled
|
|||||||||
Frame |
with elastic rubber seal |
|||||||||
Hinges |
concealed door hinges |
|||||||||
Fittings |
Top side: embedded folding ring shell
|
|||||||||
Locking |
single locking according DIN 18250
various locking systems possible |
|||||||||
Walkability
(optional) |
|
|||||||||
Opening assist |
gas spring |
|||||||||
Installation |
|
|||||||||
Marking |
external ceiling flaps marked according to EN 14351-1 |
|||||||||
Optional |
|
|||||||||
The information given refers to the usual configurations. Individual configurations may be required when combining different performance characteristics. Our team will be happy to assist you with the individual planning of your requirements. |