Grafik: Logo Franzen Feuerschutztüren
Franzen Feuerschutztüren
Zechenring 23
D-41836 Hückelhoven

phone +49(0)2433/93919‑0

Franzen fire door class EI

Single leaf fire door EIS-1/60

Franzen fire door EIS-1/60 "System Schröders"

Single-leaf fire resistance door EI2 60 / E 120 / EW 60 (120) (Sa/S200)

CE-marking marked

Fire resistance EI2 60 / E 120 / EW 60 (120 tested)
tested in accordance with EN 1634-1
classification report WFRC 302467 according to EN 13501-2

Combinable with additional performance characteristics:

Smoke control
(optional)

Sa / S200 tested according to EN 1634-3

Burglar resistance
(optional)

RC4 - classification report no. 22-5/15.119, PIV-Velbert
RC3 - classification report no. 22-4/15.117, PIV-Velbert
RC2 - classification report no. 45-47/22, PIV-Velbert
RC1 - classification report no. 212 24294, ift Rosenheim

according to DIN EN 1627 ff

Acoustic performance
(optional)

up to RW (C;Ctr) = 53 (-1;-5) dB

according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717

proof of airborne sound insulation for security doors
(measurement reports, test reports, expert opinions)

Thermal transmittance
(optional)

UD-value ≥ 1.7 W/(m²K) according to EN ISO 10077-1

Air tightness
(optional)

up to class 4 according to EN 12207 (up to 600 Pa)

expert opinion no. 11-000082-PR01
Resistance to wind load
(optional)

up to class C5 (up to 2,000 Pa) according to EN 12210

expert opinion no. 11-000082-PR01
Watertightness
(optional)

up to class 8A according to EN 12208

expert opinion no. 11-000082-PR01
Resistance to positive and negative pressure
(optional)

up to 5.000 Pa according to DIN EN 12211

expert opinion no. 16-003037-PR01
Behavior between different climates
(optional)

class 2 (d + e) according to EN 12219 (deflection)

Ability to release
(optional)

hold-open device according to DIN EN 14637

Flush with surface
(optional)

flush-mounted design FLAT

Explosion protection
(optional)
Logo ATEX For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF)
Technical data
Dimensions
(rough building dimension)
width from 625 mm to 1,500 mm
height from 1,725 mm to 3,000 mm
Door leaf

leaf thickness 68 mm to 69 mm - smooth double-walled
plate thickness 1.0 mm to 1.5 mm

  • thin rebate design
    • optional thick rebate design
    • insulating insert
      • optional insulation inlet full-face glued and pressed with cover plate
        thus particularly plane and smooth door leaf
    • Thelesol110 fire protection strip on door leaf edges (for oversize)
Frame
  • frame-system "ZNG" with flush clipped in Thelesol® fire protection strips
  • (see installation variants)
  • corner frame
  • optional enclosing frame
  • optional block frame

with elastic rubber seal
(seal type depending on performance characteristic)

Floor seal

required for smoke control, acoustic performance, air tightness

  • optional lowerable floor seal or
  • sliding seal
Glass inset
(optional)

glass dimensions and -form variable
(rectangular glass inset max. 980 mm x 2,180 mm)

minimum frieze width: 130 mm

  • optional with intermediate glass inset bars
  • optional with port-hole (ø approx. 450 mm clear view)

glass inset bars with concealed screw connection (for rectangular glass inset)

Hinges

2/3-part KO door hinges
with patented easy-running bearings as easy running doors

  • optional door hinge with 3D adjustment
Fittings
  • optional any approved handle set according to EN 1906 resp. EN 179
  • optional panic bar handle or push bar according to EN 1125
Locking

single locking according to EN 12209, depending on version multi-point locking
profile cylinder prepared (cylinder on-site)
securing pins

  • optional panic locking according to EN 179 resp. EN 1125
Self-closing

door closer according to DIN EN 1154

  • optional spring hinge for smaller doors / flaps
Installation
  • in masonry
  • in concrete
  • in mounting walls min. F60
  • in encased steel columns
  • optional blunt installation in soffit
  • optional installation on the wall plate
Marking

CE-Zeichen marking for firedoors according to EN 16034

Optional
  • lock control
  • automated opening
  • motor locks ( also in 3-way locking)
  • powder coating in RAL colors
  • prison cell doors (special locking and food flap)
  • special solutions according to request and customer requirements

The information given refers to the usual configurations. Individual configurations may be required when combining different performance characteristics.

Our team will be happy to assist you with the individual planning of your requirements.

  • Feuerschutztür ES-1-60
    Franzen EIS-1/60single leaf fire door"System Schröders"

Downloads EIS-1/60