Franzen - ceiling flaps
Double-leaf multi purpose ceiling flap DKN-2
Franzen Deckenklappe DKN-2 | |
---|---|
Double-leaf multi purpose ceiling flap | |
Installation in internal ceilings
(optional) |
according to DIN ENV 14351-2 marked |
Installation in external ceilings
(optional) |
according to DIN EN 14351-1 marked |
Thermal transmittance (optional) |
UD-value ≥ 1.2 W/(m²K) according to EN ISO 10077-1 |
Burglar resistance
(optional) |
RC4 - classification report no. 22-5/15.119, PIV-Velbert
according to DIN EN 1627 ff |
Acoustic performance
(optional) |
according to EN ISO 10140-1 / EN ISO 10140-2 / EN ISO 717 up to RW (C;Ctr) = 45 (-0;-3) dB measurement report 820SST298/8000675260-1-13, TÜV Nord, TÜV Nord (de) expert opinion 820SST298-Hrd - TÜV Nord (de) |
Air tightness
(optional) |
up to class 3 according to EN 12207 (up to 600 Pa) expert opinion no. 40-40/12.120, PIV Velbert |
Resistance to wind load
(optional) |
up to class C4 (up to 2,000 Pa) according to EN 12210 expert opinion no. 40-40/12.120, PIV Velbert |
Resistance to positive and negative pressure
(optional) |
up to 3.800 Pa according to DIN EN 12211 expert opinion no. 40-52/16.120 |
Ability to release
(optional) |
according to EN 179 |
Explosion protection
(optional) |
For installation in potentially explosive areas, please see confirmation letter Explosion protection ATEX for Franzen hinged doors (in German language) System Schröders (PDF) |
Technische Beschreibung | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Dimensions
(rough building dimension) |
|
|||||||||
Flap leaf |
leaf thickness 69 mm - smooth double-walled
|
|||||||||
Frame |
with elastic rubber seal |
|||||||||
Hinges |
concealed door hinges |
|||||||||
Fittings |
Top side: embedded folding ring shell
|
|||||||||
Lock options |
Active leaf
single locking according DIN 18250
Fixed leaf
various locking systems possible |
|||||||||
Walkability
(optional) |
|
|||||||||
Opening assist |
gas spring |
|||||||||
Installation |
|
|||||||||
Marking |
external ceiling flaps marked according to EN 14351-1 |
|||||||||
Optional |
|
|||||||||
The information given refers to the usual configurations. Individual configurations may be required when combining different performance characteristics. Our team will be happy to assist you with the individual planning of your requirements. |